Table of Contents
EN13201-2-2015 performance requirements
The standard defines the classes of street lighting installations based on the photometric requirements. EN 13201-2-2015 is geared towards the visual needs of road users and also takes into account the environmental aspects of street lighting. The standard addresses the important areas for different lighting situations, conflict zones, traffic precautions, and pedestrian crossings. It also contains information on anti-glare protection, color rendering, night use, and visual orientation.
Motorized transport class M
Classes for roads with predominantly motorized traffic. The photometric quantity considered is the mean horizontal luminance

class | L (cd/m 2 ) (≥) | U 0 (≥) | U I (≥) | T i (%) (≤) | R EI (≥) |
M1 | 2.00 | 0.40 | 0.70 | 10 | 0.35 |
M2 | 1.50 | 0.40 | 0.70 | 10 | 0.35 |
M3 | 1.00 | 0.40 | 0.60 | 15 | 0.30 |
M4 | 0.75 | 0.40 | 0.60 | 15 | 0.30 |
M5 | 0.50 | 0.35 | 0.40 | 15 | 0.30 |
M6 | 0.30 | 0.35 | 0.40 | 20 | 0.30 |
Motorized transport class C
Classes for low-speed roads and conflict zones such as intersections, roundabouts, etc. The photometric quantity considered is the mean horizontal luminance.

class | E (lx) (≥) | U 0 (≥) | T i (%) (≤) |
C0 | 50.0 | 0.40 | 10 |
C1 | 30.0 | 0.40 | 10 |
C2 | 20.0 | 0.40 | 15 |
C3 | 15.0 | 0.40 | 15 |
C4 | 10.0 | 0.40 | 15 |
C5 | 7.50 | 0.40 | 20 |
Pedestrian areas class P
Classes for pedestrian and/or bike lanes, residential streets, emergency lanes, parking lots, and sidewalks. The photometric quantity considered is the mean horizontal luminance.

class | E (lx) (≥) | E min (lux) (≥) | Ti (%) (≤) |
P1 | 15.0 | 3.00 | 20 |
p2 | 10.0 | 2.00 | 25 |
P3 | 7.50 | 1.50 | 25 |
P4 | 5.00 | 1.00 | 30 |
P5 | 3.00 | 0.60 | 30 |
P6 | 2.00 | 0.40 | 35 |
P7 | – | – | – |
Pedestrian areas class HS
Classes for pedestrian and/or bike lanes, residential streets, emergency lanes, parking lots, and sidewalks. The photometric quantity considered is the mean hemispherical luminance.

class | E hs (lx) (≥) | U 0 (≥) |
HS1 | 5.00 | 0.15 |
HS2 | 2.50 | 0.15 |
HS3 | 1.50 | 0.15 |
HS4 | – | – |
Additional Categories class EV
Added class in zones where attention must be paid to vertical elements, such as pedestrian crossings and conflict zones. The photometric quantity considered is the minimum vertical point luminance.

class | E V,min (lx) (≥) |
EV1 | 50.00 |
EV2 | 30.00 |
EV3 | 10.00 |
EV4 | 7.50 |
EV5 | 5.00 |
EV6 | 0.50 |
Additional Categories class SC
Additional class in pedestrian zones where face recognition is required for security reasons. The photometric quantity considered is the minimum semicircular point luminance.

class | E sc,min (lx) (≥) |
SC1 | 10.0 |
SC2 | 7.50 |
SC3 | 5.00 |
SC4 | 3.00 |
SC5 | 2.00 |
SC6 | 1.50 |
SC7 | 1.00 |
SC8 | 0.75 |
SC9 | 0.50 |